Three different records

Specification, test result and certificate are not interchangeable

Before approving material, establish exactly what each document represents and whether it applies to the product, production run or batch being purchased.

01 · PRODUCT SPECIFICATION

What is intended

Describes the product format and agreed targets or tolerances—such as dimensions, blend direction, packaging, EC/pH method or physical-property requirements.

02 · TEST RESULT

What was measured

Reports a result from a defined sample using a stated method. It should identify the sample or batch and should not be assumed to represent unrelated material.

03 · CERTIFICATE / DECLARATION

What is being attested

May summarize compliance, origin or another attribute. Review the issuing party, scope, date, validity and exact product covered.

Buyer checklist

What to request before commercial approval

AreaWhat to confirmWhy it matters
Product identitySKU, format, dimensions, blend direction, packaging and order quantityPrevents a document from being applied to the wrong material
Batch referenceProduction lot, batch or shipment identifier and applicable datesConnects documents and retained samples to the supplied order
EC and pHUnits, extraction ratio, sample preparation, water quality and methodDifferent methods can produce different reported values
BufferingTreatment used, process description and how the claim is verified“Buffered” alone does not define the analytical or agronomic outcome
Physical propertiesExpansion, moisture, particle distribution, fibre, bulk density, water/air propertiesThese influence handling, container fill and irrigation response
Other testingWhich tests were performed, laboratory, method, sample and resultAvoids assuming that every possible test applies to every batch
Commercial termsCurrent availability, origin, dispatch point, freight, lead time and acceptance processSeparates technical suitability from logistics and contract terms
EC and pH

Always compare results produced by compatible methods

A number without a method is incomplete. Sample-to-water ratio, extraction procedure, water quality, temperature and instrument calibration can change the reported result.

Ask for the method

  • Units and extraction ratio
  • Sample preparation and equilibration time
  • Water or extractant used
  • Laboratory or instrument reference

Ask what the number means

  • Target, typical value or acceptance limit
  • Single sample or batch composite
  • As-manufactured or post-hydration result
  • Date and batch applicability

Review in your system

  • Water analysis and fertilizer programme
  • Crop sensitivity and production stage
  • Container geometry and irrigation
  • Controlled production trial
For a deeper explanation, use Avee’s commercial EC, pH and buffering specification guide. Published website values are selection targets; the quotation and applicable documents control the commercial specification.
Sampling and traceability

A useful result begins with a representative sample

1 · IdentifyRecord product, batch, packaging unit, date and person collecting the sample.
2 · CollectUse an agreed plan across representative units rather than choosing one convenient package.
3 · TestUse the specified preparation and analytical method with calibrated equipment or laboratory controls.
4 · RetainKeep records and, where appropriate, a sealed retained sample for investigation or comparison.
Commercial workflow

Qualify the material before scaling the order

STEP 1

Define acceptance criteria

Agree on format, test methods, targets, tolerances, packaging, documents and logistics before the purchase order.

STEP 2

Review sample and documents

Confirm that samples and results represent the proposed commercial material and evaluate them through the buyer’s quality process.

STEP 3

Run a production trial

Test under the operation’s water, fertilizer, irrigation, climate and crop system before adopting the material at scale.

See the practical shipping, samples and documentation guide for quotation inputs, sample limitations and supply planning.
Frequently asked questions

Quality and documentation questions

Does every Avee product have the same EC and pH specification?

No assumption should be made across products. Confirm the target, tolerance, analytical method and applicable batch result for the exact material quoted.

Does “lab-tested” mean every possible test was performed?

No. The phrase should be tied to identified tests, methods, samples and results. Ask which tests and documents apply to the quoted product and batch.

Can a pre-shipment sample guarantee the full commercial order?

A sample supports evaluation but does not replace a written specification, representative batch controls, acceptance criteria or production-scale trial.

What should be included in a quality-related enquiry?

Send the product, crop, current specification, required test methods and limits, order quantity, destination, required date and the documents your quality team needs.

Request the documents for the product you are evaluating

Tell Avee the product, crop, specification, quantity, destination and required date. We’ll identify the targets and available documents applicable to the quoted material.

Request specifications or documents →